| Server Name: | GFP - FANUC Power Mate i using the FOCAS1/HSSB API . | ||
| Device Manufacturer: | GE FANUC | ||
| Devices Supported: | FANUC Power Mate i using the FOCAS1/HSSB API. A Power Mate I-Model D was used for testing GFP. | ||
| Protocol: | FOCAS1/HSSB API 1.6. A license to use the library must be purchased from GE FANUC. | ||
| Platform: | Windows NT Service Pack (SP) 5 or higher. | ||
| Interface Type: | FOCAS1/HSSB. The copyright of FOCAS1/HSSB is owned by FANUC Limited. The API for FOCAS1/HSSB is used for exchanging data and information between a personal computer and PMi devices using the HSSB (High Speed Serial Bus) interface. | ||
| GFP supports reading/writing data related to PMC Data Type D only (Refer to Item 9 below). | |||
| The main features of the CNC/PMC Data Window Library for FOCAS1/HSSB are given below for your reference only. Please NOTE again that all features given below are NOT supported by GFP. | |||
| 1. | CNC: Reading/writing data related to controlled axes/spindle | ||
| This data includes the absolute position, relative position, machine position, remaining distance to go, actual feedrate, etc. | |||
| 2. | CNC: Operations related to CNC program | ||
| Operations include upload/download, verification, search, and deletion of CNC programs, read CNC program directory, and DNC operation from the personal computer. | |||
| 3. | CNC: Reading/writing CNC file data | ||
| This data includes tool offset data, workpiece reference point offset data, parameters, settings, custom macro variables, P-code macro variables, and pitch error compensation data. | |||
| 4. | CNC: Reading/writing tool life management data | ||
| 5. | CNC: Reading history data | ||
| This data includes operation history data and alarm history data. | |||
| 6. | CNC: Reading servo/spindle data | ||
| 7. | CNC: Reading/writing waveform diagnosis data | ||
| 8. | CNC: Reading/writing of other data | ||
| This data includes continuous-state data, diagnostic data, A/D conversion data, alarm information, and operator messages, etc. | |||
| 9. | Reading/writing data related to PMC | ||
| This data includes addresses G, F, Y, X, A, R, T, C, and D, extended backup memory. | |||
|
FOCAS1/HSSB is realized by serial communications with a FANUC HSSB Board. Before the installation, determine the I/O port address for the HSSB board to be installed, and in case of HSSB multi-connection, the correspondence between nodes and connected PMi's. In case of i-series, I.T. type 2 which do not have the ISA extension unit, the I/O port address is fixed at 280H-28BH. Refer to FOCAS1/HSSB documentation for more information. |
|||
| Max Devices Supported: | 8 (Corresponds to maximum nodes supported) | ||
| Reference Docs: | README2.TXT File - README file for FANUC Open CNC(HSSB Type 2) Drivers and Libraries | ||
| Contact: | Dimension Software, Inc. - 1536 St. Clair Road, Taylorsville, NC 28681, USA - Voice: (828) 635-7189, Fax: (828) 625-5319, E-Mail: dsi@caro.net Web: http://www.caro.net/dsi. | ||
| Introduction |
|
This document provides general information on the features supported by GFP. When you install the OPC Server, you should also review the sections titled: About the I/O Driver, How Do I…, Setting up The I/O Driver, OPC Addressing and Using the PowerTool in the GFP electronic documentation. To get there, click on Help and Help Topics on the PowerTool menu bar. The PowerTool is a client application with a graphical user interface that accesses the GFP OPC Server and lets you view and modify communications channel, device, and datablock properties. |
| Features |
| GFP includes the following features: |
|
Feature |
Feature Description |
|
1 |
PowerTool – OPC Server has a user interface called the PowerTool for configuring channels, devices, |
|
2 |
The PowerTool has a built-in datascope for checking Host-to-CNC and CNC-to-Host communications |
|
3 |
PowerTool has context sensitive help. |
|
4 |
Server automatic reads after a write to confirm a write. |
|
5 |
Automation Interface - You don't have to use the Power Tool to configure the driver. You can make your own COM or OLE application (using Microsoft's Visual Basic) to configure the driver and access data. |
|
6 |
Secondary Poll Rate - The OPC Server polls a datablock at the secondary poll rate once the Access Time expires. Data is polled at the secondary poll rate until there is another client request for data. If the secondary poll rate is set for a longer period of time than the Primary Rate, CPU resources are reduced while ensuring that the datablock will always be polled. |
|
7 |
Phased Poll Rates. |
|
8 |
Enable/Disable individual communication channels, devices, and datablocks from the automation |
| FOCAS1/HSSB Functions Supported |
| The PMi/PMC API for FOCAS1/HSSB functions supported are shown in Table 1. They are described in reference to the FOCAS1/Ethernet CNC/PMC Data window library function call. |
| Table 1 – GFP Function Calls Supported |
|
Function Call |
Description |
|
cnc_allclibhnd12 |
Allocate library handle |
| cnc_freelibhndl | Frees library handle |
| pmc_rdpmcrng |
Read D type (Data Table) PMC data. GFP supports 4000 D
registers in the range D0 to D7998 (even addresses only).
Registers must be defined on the CNC side as Read/Write enabled. |
| pmc_wrpmcrng | Write D type (Data Table) PMC data. |
| OPC Addressing Information |
| OPC Server item ID's for GFP use the following format: |
| <Address>[[[|<Signal Conditioning>],<Low EGU>],<High EGU>] |
| where: |
| <Address> | is the I/O Address of the data item requested. The <Address> field is required. The <Address> field has the format: DeviceName:Address[:Bit] where: | |
| DeviceName | The name of the hardware device that contains the data you want to access. The device name is user assigned in the GFP PowerTool. |
|
| Address | The register address you wish to access. For digital points, you can address a byte (use even and odd addresses). |
|
| Bit | Bit number (Bit 0 = LSB and bit 7 = MSB). This parameter is used for digital access only. | |
| <Signal Conditioning> | (optional) is the type of Signal Conditioning desired for the specified address. The default is "None". The "|" character must separate the <Address> and <Signal Conditioning> fields. This field is only used for analog points. | |
| <Low EGU> | (optional) is the low EGU limit for the specified address. The default is 0. This field is only used for analog points. | |
| <High EGU> | (optional) is the high EGU limit for the specified address. The default is 65535. This field is only used for analog points. | |
| Note that only the <Address> field is required. All other fields are optional, and are only used for analog values. |
| The Low and High EGU fields (and the % deadband value specified for a client group) are used by the OPC Server in deadband calculations. The deadband calculation specifies when the OPC server will update a client with new data. If no Low and High EGU fields are entered, the default is 0-65535. |
| Signal Conditioning |
Signal Conditioning Name: |
Description: |
|
NONE |
No Scaling |
|
LIN (Unsigned) |
Scales 16-bit unsigned values to the database block's EGU range. |
|
LIN (Signed) |
Scales 16-bit signed values to the database block's EGU range. |
|
3BCD |
Scales 3-digit Binary Coded Decimal values to the database block's EGU range. |
|
4BCD |
Scales 4-digit Binary Coded Decimal values to the database block's EGU range. |
|
8BN |
Scales 8-bit binary values to the database block's EGU range. Ignores the most significant byte. No Alarming on Out of Range. |
|
8AL |
Scales 8-bit binary values to the database block's EGU range. Ignores the most significant byte. Alarming on Out of Range. |
|
12BN |
Scales 12-bit binary values to the database block's EGU range. Ignores the most significant nibble (4-bits). No Alarming on Out of Range. |
|
12AL |
Scales 12-bit binary values to the database block's EGU range. Ignores the most significant nibble (4-bits). Alarming on Out of Range. |
|
13BN |
Scales 13-bit binary values to the database block's EGU range. Ignores the most significant 3 bits. No Alarming on Out of Range. |
|
13AL |
Scales 13-bit binary values to the database block's EGU range. Ignores the most significant 3 bits. Alarming on Out of Range. |
|
15BN |
Scales 15-bit binary values to the database block's EGU range. Ignores the most significant bit. No Alarming on Out of Range. |
|
15AL |
Scales 15-bit binary values to the database block's EGU range. Ignores the most significant bit. Alarming on Out of Range. |